Page 56 of 56
If a channel has a numeric value of 0xff or an alpha value of ‘*’, the command is to be applied to all channels.
For example, a group value of 0x3 and a channel value of 0xff would mean that the command is to be applied
to all channels of group 3 (Mic inputs).
Interact AT Meter Type Definitions
Alpha Numeric
Level
position for
Microphones
Level position for
Line Inputs and
Outputs
Level position for USB In, USB
Out, Telco Receive & Telco
Transmit
A 2
Level after
processing
Level after PEQ
and gain
Level after gain
R 5
Echo Return
Loss
N/A N/A
E 6
Echo Return
Loss
Enhancement
N/A N/A
T 7 ERL + ERLE N/A N/A
B 12
Pre PEQ,
Post Gain
N/A N/A
Interact PRO Meter Type Definitions
Alpha Numeric
Level of
Microphones
Level for Line
Inputs, Outputs,
USBIn, USB
Out, Headset
In, Headset Out
&Telco TX
Level for
Telco RX
Level for
Virtual
Reference
Level for
Processing
Channels
I 1 Input Input Input
Input to
compressor
A 2 After Gain After Gain After Gain Output
Amount of
Compression
N 3 Output Level
G 4 After Gate
R 5
Echo Return
Loss (Room
Loss or ERL)
Echo Return
Loss (ERL)
E 6
Echo Return
Loss
Enhancement
(ERLE)
Echo Return
Loss
Enhancement
(ERLE)
T 7
Total Echo
Return Loss
(ERL+
ERLE)
Total Echo
Return Loss
(ERL+
ERLE)
Comentários a estes Manuais