Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • http://www.gentner.com
Page 6 Audio Perfect
TM
10 Installation and Operations Manual
G-LINK NETWORK NOTE:
If the Gentner units to be networked are stacked vertically, connect them using the
short RJ45 jumper (provided). If networking Gentner units (maximum distance 20
feet between units), Gentner Communications recommends that category five twisted-
pair (10BaseT LAN) cable be used.
The first Gentner unit in the chain must have the G-LINK IN connector [2]
terminated with a G-Link terminator (provided). The first Gentner unit’s G-
LINK OUT connector [3] is then attached to the G-LINK IN [2] connector on
the next unit in the chain. At the end of the network, the final unit must have the
G-LINK OUT connector [3] terminated with a G-Link terminator as well. A G-
Link network will allow interconnection of up to 16 AP10s and eight AP800s.
Step 5 — Device ID (Dip Switches 9–12)
Once your physical G-Link network is established, you need to set up unique G-
Link device ID numbers for each AP10 on the network. As shipped from the
factory, all AP10 units default as binary address 0. Set Device ID numbers for
each Gentner unit at your site by manipulating front-panel dip switches 9–12,
selecting/deselecting each switch to set up address 0–15 in binary code. Table 1
(below) illustrates how this is done.
Set the device ID for each AP product on the G-Link network.
DEVICE ID CONFLICT ERROR NOTE:
If more than one AP10 is assigned the same device ID number, the TRANSMIT and
RECEIVE LEDs will flash back and forth on the affected units until the error is
corrected.
Installation
Continued
Figure 10. AP10 power module
Step 6 — Power Connection
The power cord [1] (See Figure 10, left) will operate at any level between 100–
240Vac, 50–60Hz, 30W.
Hardware installation is now complete.
Table 1. Device ID Dip
Switch Settings
Binary Dip Switch 9 Dip Switch 10 Dip Switch 11 Dip Switch 12
Address Position Position Position Poisition
0 0 (DOWN) 0 (DOWN) 0 (DOWN) 0 (DOWN)
1 0 (DOWN) 0 (DOWN) 0 (DOWN) 1 (UP)
2 0 (DOWN) 0 (DOWN) 1 (UP) 0 (DOWN)
3 0 (DOWN) 0 (DOWN) 1 (UP) 1 (UP)
4 0 (DOWN) 1 (UP) 0 (DOWN) 0 (DOWN)
5 0 (DOWN) 1 (UP) 0 (DOWN) 1 (UP)
6 0 (DOWN) 1 (UP) 1 (UP) 0 (DOWN)
7 0 (DOWN) 1 (UP) 1 (UP) 1 (UP)
8 1 (UP) 0 (DOWN) 0 (DOWN) 0 (DOWN)
9 1 (UP) 0 (DOWN) 0 (DOWN) 1 (UP)
10 (A) 1 (UP) 0 (DOWN) 1 (UP) 0 (DOWN)
11 (B) 1 (UP) 0 (DOWN) 1 (UP) 1 (UP)
12 (C) 1 (UP) 1 (UP) 0 (DOWN) 0 (DOWN)
13 (D) 1 (UP) 1 (UP) 0 (DOWN) 1 (UP)
14 (E) 1 (UP) 1 (UP) 1 (UP) 0 (DOWN)
15 (F) 1 (UP) 1 (UP) 1 (UP) 1 (UP)