Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • http://www.gentner.com
Page 8 Audio Perfect
TM
10 Installation and Operations Manual
Dip Switch 5, Auto-Disconnect
Dip switch 5 behind the AP10’s front access panel enables/disables auto-
disconnect (Table 6, below).
Dip Switch 6, Call Progression/Loop
Dip switch 6 selects either loop drop or call-progress mode. Call-progress mode
will disconnect the line upon detection of a valid call-progress signal (Table 7,
below). Call progress will detect reorder tone and busy for the U.S., Canada,
United Kingdom, France and Germany.
Operational Features
Continued
Table 5. Auto-Answer Dip Switch Settings
Dip Switch Position Description
4 ON (UP) Auto-answer enabled
4* OFF (DOWN) Auto-answer disabled (follows the serial command)
AUTO-ANSWER SERIAL COMMAND NOTE:
To issue the AA (auto-answer) serial command to toggle auto-answer, the dip switch 4 must be OFF (DOWN).
Table 6. Auto-Disconnect Dip Switch Settings
Dip Switch Position Description
5* ON (UP) Auto-disconnect enabled
5 OFF (DOWN) Auto-disconnect disabled
Dip Switch 7, Receive Reduction
In some applications, it may be necessary to duck the receive audio coming in
through the telephone line when transmit audio is present. To serve this purpose,
dip switch 7 is designated to duck the receive audio by -6dB, if active (Table 8,
below).
Dip Switch 8, Hook-Flash Duration
Dip switch 8 selects either a 50 millisecond or 500 millisecond hook-flash duration
(Table 9, below).
AUTO-DISCONNECT NOTE:
In order for the settings on Dip Switch 6 (below) to function, Dip Switch 5 (above) must be ON (UP). Auto-disconnect must
be enabled before either Call Progression or Loop Drop are applicable.
Table 8. Receive Reduction Dip Switch Settings
Dip Switch Position Description
7 ON (UP) Receive reduction enabled
7* OFF (DOWN) Receive reduction disabled
Table 7. Call Progression/Loop Dip Switch Settings
Dip Switch Position Description
6 ON (UP) Call progression enabled
6* OFF (DOWN) Loop drop enabled
Table 9. Hook-Flash Duration Dip Switch Settings
Dip Switch Position Description
8 ON (UP) 50 milliseconds
8* OFF (DOWN) 500 milliseconds
Comentários a estes Manuais